Reflective Aluminum Foil Insulation
RAC-60B

  Construction:
 

Construction

Composition

Description

Value (English)

Value (Metric)

Foil

Aluminum

0.28 mil

7 micron

Thread - MD

Fiberglass

2 / inch

8 / 100mm

Thread - XD

2 / inch

8 / 100mm

Adhesive

Polyethylene

--

--

Kraft

Natural

36.6 lbs / 3000 ft2

60gsm

Adhesive

Polyethylene

--

--

Foil

Aluminum

0.28 mil

7 micron

 

Typical Physical Property

Physical Property

Test Method

Value (English)

Value (Metric)

Basis Weight

Scale

26.5 lbs / 1000 ft2

130 gsm

Permeance

ASTM E96

0.02 perm

1.15 ng/N.s

Tensile Strength - MD

ASTM D828

34 lbs/In

150 N/25mm

Tensile Strength - XD

22.6 lbs/In

100 N/25mm

Burst Strength

ASTM D774

57 psi

40 N/cm2

Temperature Resistance

ASTM C1263
- 29 °C/+66 °C

Flexible
No Delamination

Flexible
No Delamination

Emissivity

ASTM E408

0.03

0.03

Applications

Our aluminum foil insulation are mainly used under roof decking, under attic rafters, over existing attic insulation, in floors, walls and crawl spaces, and in industrial and commercial buildings to block radiant heat coming into house through the roof during the summer and retain indoor heat generated during the winter. Also used as a moisture vapor barrier in air conditioning ductworks and cold rooms. Different lengths are available.

Available Roll Width: 1.25m, 1.3m
Remarks
1. Above data are typical results and not the guaranteed performance.
2. Tolerance: Weight and Thickness: ±10%; Width: ±2mm; Length: ±0.5%.
3. The products should be stored at room temperature away from wet and heat source.
4. Please do tria-application and make sure the product can serve the specific application before actually put it to use.

 